  • Common Faults and Practical Solutions for High-Low Temperature Humidity Test Chambers
    Nov 19, 2025
    High and low temperature humidity test chambers are key reliability testing equipment, widely used in electronics, automotive and biomedicine. Their stability directly affects test accuracy. This article summarizes common faults and solutions for efficient troubleshooting. I. Temperature-related Faults: Core Impact on Test Accuracy 1. Failure to Reach Set Temperature Fault Performance: Fails to reach target temperature when heating; slow or no cooling.Possible Causes: Abnormal power voltage, burned heater, compressor failure, fan stop, air duct blockage.Solutions: Verify power matches rated specs (220V/380V); check fan operation and clean duct debris; contact professionals to replace faulty parts if heater/compressor fails. 2. Large Temperature Fluctuation and Poor Uniformity Fault Performance: Excessive temperature difference in the chamber or frequent fluctuations near set value.Possible Causes: Abnormal fan speed, damaged air duct seals, over-dense samples blocking airflow.Solutions: Arrange samples for ventilation; check fan stability and replace damaged seals promptly. 3. Severe Temperature Overshoot Fault Performance: Temperature overshoots set value significantly before dropping.Possible Causes: Improper controller settings, energy regulation system failure.Solutions: Restart to reset parameters; if unresolved, have technicians calibrate controller or overhaul regulation modules. II. Humidity-related Faults: Directly Linked to Test Environment Stability 1. Failure to Reach Set Humidity Fault Performance: Slow or no humidification.Possible Causes: Empty humidification tank, faulty water level sensor, burned humidifier tube, blocked solenoid valve.Solutions: Replenish water; clean valve filter; replace tube or repair sensor if humidifier fails to heat. 2. High Humidity That Cannot Be Reduced Fault Performance: Humidity remains above set value; dehumidification fails.Possible Causes: Faulty dehumidification system, poor chamber sealing, high ambient humidity.Solutions: Check door seals and reduce ambient humidity; report for repair if dehumidification module fails. 3. Abnormal Humidity Display Fault Performance: Humidity reading jumps, disappears or deviates greatly from reality.Possible Causes: Aging humidity sensor, contaminated probe.Solutions: Wipe probe with clean cloth; calibrate or replace sensor if inaccuracy persists. III. Operation and Circulation Faults: Ensure Basic Equipment Operation 1. Fan Not Rotating or Making Abnormal Noise Possible Causes: Motor damage, foreign objects in fan blades, worn bearings.Solutions: Clean debris after power-off; replace motor or bearings if fault persists. 2. Compressor Abnormality Fault Performance: Compressor fails to start or stops frequently after starting.Possible Causes: Power phase loss, overload protection trigger, refrigerant leakage.Solutions: Check three-phase wiring; retry after overload reset; report for refrigerant and compressor inspection if fault recurs. 3. Equipment Alarm Fault Performance: Alarms like "phase loss" or "overload" activate.Possible Causes: Triggered protection from wrong phase sequence, unstable voltage or overheated components.Solutions: Troubleshoot per alarm; restart after 30-minute cooldown for overload; report if ineffective. IV. Core Notes 1. Always power off before troubleshooting to avoid shock or component damage.2. Contact professionals for complex repairs (compressors, refrigerants, circuit boards); do not disassemble yourself.3. Regularly clean air ducts, filters and sensors to reduce over 80% of common faults.
    続きを読む
  • User Preparation Before Delivery of High and Low Temperature (Humidity) Test Chamber
    Nov 15, 2025
    1. Preparation for Load-bearing and Dimensional Adaptation • The load-bearing capacity of the site floor shall strictly meet the core requirement of ≥500kg/m², which is a key prerequisite for ensuring the long-term stable operation of the equipment and avoiding equipment deformation or safety hazards caused by insufficient load-bearing capacity. • It is necessary to accurately confirm the external dimensions of the test chamber specified in the technical specification in advance. Combined with the on-site actual survey of the transportation and installation path, ensure that the equipment can smoothly pass through all key passage nodes such as elevators, laboratory doors and corridors, so as to avoid delay in delivery and installation due to inconsistent dimensions. 2. Preparation for Installation Site Conditions • The floor of the installation site shall be flat without protrusions and depressions, and the ventilation conditions shall meet the basic standards for equipment operation. At the same time, there shall be no flammable, explosive, corrosive gases or dust in the environment, as such substances will seriously affect the service life of equipment components and the accuracy of test data. • Strong electromagnetic radiation sources such as high-voltage lines and large motors should be actively avoided near the equipment installation location, as strong electromagnetic interference may cause disorder of the equipment control system, thereby affecting the temperature and humidity control accuracy of the test chamber. • A floor drain that meets the drainage standards must be provided within 2 meters of the equipment's refrigeration unit. This requirement is to timely discharge the condensed water generated during the operation of the refrigeration system, so as to avoid water accumulation soaking the equipment or polluting the site environment. • Sufficient maintenance and operation space shall be reserved around the equipment in accordance with specifications. The specific requirements strictly follow the following standards: Area A ≥80cm, Area B ≥60cm, Area C ≥110cm, Area D ≥110cm. Sufficient space is a necessary guarantee for later equipment maintenance, calibration and component replacement.
    続きを読む
  • High-Low Temperature and Humidity Test Chamber: Comprehensive Safety Protection
    Nov 14, 2025
    Widely used in electronics, automotive, aerospace, etc. It tests product reliability by simulating extreme environments and is key equipment for product quality and safety. 1. Refrigeration system safety protection Compressor overpressure protection: Activates pressure relief when overpressure, preventing explosion and ensuring safety. Compressor overheating protection: Monitors temperature in real time, cuts power when exceeding threshold to avoid burnout and extend life. Compressor over-current protection: Monitors current, cuts power when exceeding rated value to prevent overload or motor damage. 2. Test area safety protection Adjustable over-temperature protection: Flexible threshold setting, automatically controls temperature (reduces power, starts cooling) when exceeding, protecting samples and equipment. First-layer high/low temperature over-temperature protection: Sets high/low temperature protection values for operating temperature, stops heating/cooling when exceeding range. Second-layer high-temperature over-temperature protection: Electronic device with high-precision detection, cuts heating power when exceeding first-layer range. Third-layer high-temperature over-temperature protection: Last barrier, cuts all heating power and alarms when first two layers fail. Fault protection: Cuts control power when faulty, indicates cause and outputs alarm for easy troubleshooting. 3. Other safety protections Total power phase sequence and open-phase protection: Monitors phase sequence and open-phase, cuts power when abnormal to prevent damage. Short-circuit protection: Quickly cuts circuit (fuse blowing, breaker tripping) during short circuit to avoid fire, etc. Leakage/surge protection: ELB prevents electric shock, fuse protects circuit, RC device suppresses surges. Water-cut and dry-burning protection: Cuts power for humidity-related equipment and electric heating when water is cut off to prevent dry burning. 4. Summary     The safety protection system of the high-low temperature and humidity test chamber covers core working units and key auxiliary links, forming a comprehensive and multi-level protection closed loop. Through accurate monitoring, rapid response and effective intervention, each protection device not only ensures the long-term stable operation of the equipment and extends its service life, but also safeguards the safety of test samples and personnel operation. It serves as the core support for reliable test processes and accurate results, building a solid safety barrier for product quality verification.
    続きを読む
  • Differences between High and Low Temperature Test Chamber and Constant Temperature Test Chamber
    Nov 13, 2025
        In environmental reliability testing, high-low temperature humidity test chambers and constant temperature and humidity test chambers are easily confused due to similar names, but they differ significantly in testing capabilities, applications and technical characteristics. Accurate distinction and selection are key to ensuring valid test data. This blog will analyze the core differences and provide selection suggestions. I. Core Definition: Essential Distinction of Functional Boundaries     The core difference between the two starts with functional positioning, which directly determines the applicable scenarios.     The core of the constant temperature and humidity test chamber is "maintaining stability". It can accurately control and maintain the set temperature and humidity for a long time, and is used to simulate the long-term performance of products in specific environments, such as electronic component stability testing and textile temperature-humidity sensitivity testing. Its core requirement is "steady-state environmental performance verification".     The high-low temperature humidity test chamber focuses on "dynamic simulation". In addition to precise temperature and humidity control, it has a wide-range fluctuation capability, which can simulate environments such as high-low temperature cycles and alternating humidity and heat, such as extreme temperature differences during product transportation and diurnal temperature-humidity changes of outdoor equipment. Its core requirement is "dynamic environmental reliability verification". II. Key Differences: Multi-dimensional Analysis from Technology to Application 1. Temperature and Humidity Range and Fluctuation Capacity     The constant temperature and humidity chamber has a mild temperature and humidity range (temperature 0℃-100℃, humidity 30%-95%RH) and high control precision (temperature fluctuation ±0.5℃, humidity ±2%RH), but no extreme temperature-humidity impact capability.     The high-low temperature humidity chamber has a wider temperature and humidity coverage (temperature -70℃~200℃, humidity 10%-98%RH) and rapid change capability (heating rate 3℃/min-15℃/min, cooling rate 1℃/min-10℃/min), which can realize rapid cycle switching between "high temperature and high humidity - low temperature and low humidity"—a feature unavailable in the former. 2. Differences in Core Technical Architecture     The constant temperature and humidity chamber adopts single-stage compression refrigeration, conventional resistance heating, and steam or ultrasonic humidification. Its system design focuses on "energy saving and stability", with simple structure and low operating cost.     To meet extreme needs, the high-low temperature humidity chamber uses cascade refrigeration, rapid-heating tubes, and its humidity system includes a fast-response dehumidification module, with a thicker insulation layer on the chamber wall. Its technical complexity and manufacturing cost are much higher than the former. 3. Applicable Scenarios and Testing Purposes     The constant temperature and humidity chamber is used for steady-state environmental adaptability testing, such as electronic component aging and pharmaceutical storage simulation, to verify the performance consistency and durability of products in a fixed environment.     The high-low temperature humidity chamber focuses on dynamic reliability testing, such as high-low temperature cycling of auto parts and extreme environment simulation of aerospace products, to expose product defects (material aging, structural deformation, etc.) under drastic environmental changes.     In summary, the constant temperature and humidity chamber guards the steady-state environment, while the high-low temperature humidity chamber challenges the dynamic environment. There is no absolute advantage or disadvantage between the two. Only by matching needs, clarifying scenarios and budgets can the test truly guarantee product quality.
    続きを読む
  • How is over-temperature protection carried out in a temperature test chamber?
    Oct 23, 2025
    The over-temperature protection of the temperature test chamber is a multi-level and multi-redundant safety system. Its core purpose is to prevent the temperature inside the chamber from rising out of control due to equipment failure, thereby protecting the safety of the test samples, the test chamber itself and the laboratory environment.   The protection system usually consists of the following key parts working together: 1. Sensor: The main sensor is used for the normal temperature control of the test chamber and provides feedback signals to the main controller. An independent over-temperature protection sensor is the key to a safety system. It is a temperature-sensing element independent of the main control temperature system (usually a platinum resistance or thermocouple), which is placed by strategically at the position within the box that best represents the risk of overheating (such as near the heater outlet or on the top of the working chamber). Its sole task is to monitor over-temperature. 2. Processing unit: The main controller receives signals from the main sensor and executes the set temperature program. The independent over-temperature protector, as an independent hardware device, is specifically designed to receive and process the signals from the over-temperature protection sensor. It does not rely on the main controller. Even if the main controller crashes or experiences a serious malfunction, it can still operate normally. 3. Actuator: The main controller controls the on and off of the heater and the cooler. The safety relay/solid-state relay receives the signal sent by the over-temperature protector and directly cuts off the power supply circuit of the heater. This is the final execution action.   The over-temperature protection of the temperature test chamber is a multi-level, hard-wire connected safety system designed based on the concepts of "redundancy" and "independence". It does not rely on the main control system. Through independent sensors and controllers, when a dangerous temperature is detected, it directly and forcibly cuts off the heating energy and notifies the user through sound and light alarms, thus forming a complete and reliable safety closed loop.
    続きを読む
  • 急速温度変化試験室の設置場所の選定 急速温度変化試験室の設置場所の選定
    Jun 27, 2025
    急速温度変化試験室の設置場所の選定: 隣接する壁からの距離は、環境試験室の役割と特性をスムーズに発揮させるために重要です。長期間にわたって15~45℃の温度と86%を超える相対環境湿度が確保できる場所を選択してください。 設置場所の動作温度は大きく変化してはなりません。 水平な面に設置する必要があります(設置時に道路の水平を確認するために水準器を使用してください)。 日光が当たらない場所に設置してください。 自然換気が良好な場所に設置してください。 可燃性物質、爆発性物質、高温熱源が除去された場所に設置する必要があります。 ほこりの少ない場所に設置してください。 電源システムのスイッチング電源にできるだけ近い場所に設置してください。
    続きを読む
  • 高温・低温試験槽に問題が発生した場合はどうすればよいですか? 高温・低温試験槽に問題が発生した場合はどうすればよいですか?
    Jun 23, 2025
    高温・低温試験室 使用の過程でさまざまな問題が発生する可能性がありますが、以下にさまざまな観点から潜在的な障害とその原因をまとめます。1. コアシステム障害温度が制御不能理由: PID 制御パラメータのバランスが崩れ、周囲温度が機器の設計範囲を超え、複数のゾーンの温度が干渉します。事例: 特殊な環境の作業場では、外部の高温により冷凍システムに過負荷がかかり、温度ドリフトが発生します。湿度が異常です理由:加湿水質が悪いと、スケールやノズルの詰まり、超音波加湿器の圧電シートの故障、除湿乾燥剤の再生不良が発生します。特殊現象:高湿度テスト中に逆結露が発生し、ボックス内の実際の湿度が設定値よりも低くなります。2. 機械的および構造的な問題空気の流れが乱れている性能:サンプルエリアには3℃以上の温度勾配があります。根本原因: カスタマイズされたサンプル ラックによって元の設計の空気ダクトが変更され、遠心ファン ブレードに汚れが蓄積して動的バランスが崩れました。 シーリング不良新たな不具合:低温時に電磁密閉ドアの磁力が低下し、-70℃を超えるとシリコン密閉ストリップが脆くなり、ひび割れが発生します。3. 電気および制御システムインテリジェント制御の失敗ソフトウェア レベル: ファームウェアのアップグレード後、温度デッド ゾーンの設定エラーが発生し、履歴データのオーバーフローによりプログラムがクラッシュします。ハードウェア レベル: SSR ソリッド ステート リレーの故障により継続的な加熱が発生し、バス通信がインバータの電磁干渉の影響を受けます。セキュリティ保護の脆弱性隠れた危険: 三重温度保護リレーの同期障害と冷媒検出器の校正期限切れによる誤報。4. 特殊な労働条件の課題特定の温度ショック問題: -40℃から+150℃への急激な変化により蒸発器の溶接部に応力割れが生じ、熱膨張係数の差により観察窓のシールが破損します。長期運転減衰性能低下: 2000 時間の連続運転後、コンプレッサーのバルブ プレートの摩耗により、冷凍能力が 15% 低下し、セラミック加熱管の抵抗値が変化してしまいます。5. 環境とメンテナンスへの影響インフラの適応事例:電源電圧の変動によるPTCヒーターの電力振動と冷却水システムのウォーターハンマー効果により、プレート式熱交換器が損傷しました。予防保守の盲点教訓: ボックスの正圧を無視すると、ベアリング室に水が入り込み、バイオフィルムが増殖して凝縮水排出パイプが詰まることになります。6. 新興技術の問題点新しい冷媒の応用課題: R404A を R448A に置き換えた後のシステム オイルの適合性の問題、および亜臨界 CO₂ 冷凍システムの高圧シールの問題。IoT統合のリスク障害: リモート制御プロトコルが悪意を持って攻撃され、プログラムの改ざんやクラウド ストレージ障害が発生し、テスト証拠チェーンが失われます。戦略の推奨事項インテリジェント診断: 振動アナライザーを設定してコンプレッサーベアリングの故障を予測し、赤外線サーモグラフィーを使用して電気接続ポイントを定期的にスキャンします。信頼性設計: 蒸発器などの主要部品は耐腐食性を向上させるために SUS316L ステンレス鋼で作られており、制御システムには冗長温度制御モジュールが追加されています。メンテナンス革新:稼働時間に基づいて動的なメンテナンス計画を実施し、年間冷媒純度検査システムを確立します。これらの問題に対する解決策は、機器の具体的なモデル、使用環境、保守履歴などを考慮して分析する必要があります。機器のOEM、第三者試験機関、ユーザーの技術チームを含む共同保守体制の構築が推奨されます。重要な試験項目については、試験の継続性を確保するために、デュアルマシンホットスタンバイシステムを構成することをお勧めします。
    続きを読む
  • Lab Companion の配信基準は何ですか? Lab Companion の配信基準は何ですか?
    Jun 23, 2025
    (1)機器の設置と試運転オンサイトサービス:技術者が無料で商品をお届けし、機械組立、電気配線、デバッグ作業を行います。デバッグパラメータは、お客様との技術契約で定められた温度、湿度、塩水噴霧の付着量、その他の指標を満たす必要があります。受入基準:第三者による測定レポートを提出し、不合格となった機器は直ちに返却または交換する。例えば、降雨試験ボックスは100%合格とする。(2)顧客研修制度操作トレーニング: 機器の起動と停止、プログラム設定、日常のメンテナンスをカバーし、品質検査機関や自動車企業などのさまざまなユーザーシナリオに合わせてカスタマイズされます。徹底したメンテナンストレーニング:故障診断(高温・低温・高湿度試験室における湿度システムのトラブルシューティングなど)やスペアパーツの交換など、お客様の自主メンテナンス能力の向上を図ります。(3)技術支援と対応即時対応: 修理要求に 15 分以内に応答し、日常的な障害を 48 時間以内に解決します (遠隔地との交渉)。リモート診断: ビデオガイダンスまたはリモート アクセス ソフトウェアを使用して、問題 (砂試験室内の異常な粉塵濃度など) を迅速に特定します。(4)スペアパーツの供給とメンテナンススペアパーツ計画を立て、協力機関(中国鉄道検査認証センター、中国電子科技集団など)からの消耗部品の供給を優先し、ダウンタイムを短縮します。保証期間中の非手動による損傷は無料で、保証期間後は明確な料金で有料サービスが提供されます。
    続きを読む
  • 充電式電池の環境試験
    Feb 21, 2025
    使用後に充電することで再活性化できる二次電池。環境対応車、電力貯蔵、動力分野などで幅広く使用されています。充電式バッテリーの環境テストは、さまざまな環境条件下でのバッテリーの性能を評価する重要な手段です。Ⅰ. テストの目的充電式バッテリーの環境テストは、実際の使用環境で遭遇する可能性のあるさまざまな条件をシミュレートして、バッテリーの信頼性と性能を評価することを目的としています。テストを通じて、さまざまな温度、湿度、振動、衝撃などの条件下でのバッテリーの動作状態を把握することができ、バッテリーの研究開発、生産、使用に科学的根拠を提供します。Ⅱ. テスト内容A. 温度テストa. 高温テスト:高温環境下で温度安定性と熱暴走のリスクを観察します。b. 低温試験:低温条件下でのバッテリーの放電性能、容量劣化、低温始動能力を試験します。c. 温度サイクルテスト: バッテリーの実際の使用時に発生する可能性のある温度変化をシミュレートし、熱耐久性とサイクル寿命を評価します。B. 湿度テスト: 湿度の高い環境でのバッテリーの性能、密閉性、耐腐食性を評価します。C. 振動テスト: 輸送、設置、使用中に発生する可能性のある振動環境でバッテリーをシミュレートすることにより、構造の完全性、電気接続の信頼性、性能の安定性を評価します。D. 衝撃テスト:落下や衝突などの予期しない状況でバッテリーをシミュレートし、耐衝撃性を評価します。E. 外部短絡試験:熱暴走や爆発などのリスクを含む外部短絡条件下でのバッテリーの性能をテストします。Ⅲ. 試験基準と仕様充電式バッテリーの環境テストでは、テスト結果の正確性と比較可能性を確保するために、関連するテスト標準と仕様に従う必要があります。一般的なテスト標準には次のものがあります。IEC 62133/IEC 61960、UN 38.3、UL 1642/UL 2580、GB/T 31467、JIS C 8714Ⅳ. 試験装置充電式バッテリーの環境試験には専門的な試験装置と方法が必要です。一般的な試験装置には以下のものがあります:高温・低温試験室: さまざまな温度環境をシミュレートするために使用されます。湿度試験室:湿度の高い環境でのバッテリーの性能を評価するために使用されます。振動テストベンチ: 振動環境をシミュレートして、バッテリーの構造的完全性と性能安定性を評価します。衝撃試験機: 落下や衝突などの予期しない状況での衝撃をシミュレートするために使用されます。Ⅴ. テスト結果と評価テストが完了したら、テスト結果を分析および評価する必要があります。テストデータと標準要件に基づいて、さまざまな環境条件下でバッテリーの性能が要件を満たしているかどうかを判断します。望ましくないバッテリーについては、さらに分析し、対応する改善措置を講じる必要があります。要約すると、充電式バッテリーの環境テストは、実際の使用においてバッテリーの安定した信頼性の高いパフォーマンスを確保するための重要な手段です。専門的なテスト機器は、充電式バッテリーのテストに対してより専門的で安全、科学的かつ効果的な実験結果を提供し、テストのコストを大幅に削減し、企業に利便性をもたらします。クリックして関連商品を確認してください。 https://www.lab-companion.com/thermal-shock-test-chamberhttps://www.lab-companion.com/温度-アンド-湿度-チャンバーhttps://www.lab-companion.com/rapid-temperature-cycling-test-chamber  
    続きを読む
  • 太陽放射シミュレーション試験室の紹介 太陽放射シミュレーション試験室の紹介
    Oct 16, 2024
    太陽放射シミュレーション試験室の紹介太陽光模擬照射試験室は、「太陽光放射線防護試験装置」とも呼ばれ、試験基準と試験方法によって、空冷キセノンランプ(LP/SN-500)、水冷キセノンランプ(LP/SN-500)、卓上キセノンランプ(TXE)の3種類に分かれています。試験温度、湿度、精度、時間などに違いがあり、老化試験室シリーズに欠かせない試験機器です。試験室では、人工光源とG7 OUTDOORフィルターを組み合わせて、自然光の放射をシミュレートすることで、システム光源を調整し、太陽光シミュレータのIEC61646の要件を満たします。上記のシステム光源は、太陽電池モジュールのIEC61646光老化試験を実施するために使用され、試験中はモジュールの背面の温度を50±10℃の間で常に制御する必要があります。温度を自動的に監視できます。放射計を構成して光の放射照度を制御し、指定されたレベルで安定していることを確認すると同時に、試験時間を制御します。太陽光模擬照射試験室における紫外線サイクル期間中、光化学反応は通常、温度の影響を受けにくい。しかし、その後の反応の速度は温度に依存します。これらの反応の速度は、温度が上昇するにつれて加速します。したがって、紫外線照射中の温度制御は非常に重要です。さらに、加速老化試験の温度は、材料が太陽光に直接さらされる最高温度と一致するようにする必要があります。太陽光模擬照射試験室では、照度と周囲温度に基づいて、紫外線照射温度を 50 ℃ ~ 80 ℃ の任意の温度に設定できます。紫外線照射温度は、感度の高い温度コントローラと送風システムによって調整され、この試験室の温度の優れた均一性を実現します。お客様各位:こんにちは、当社は優れた技術力を備えた高品質の開発チームであり、高品質の製品、完全なソリューション、優れた技術サービスをお客様に提供しています。主な製品は次のとおりです。 ウォークイン恒温恒湿試験室、紫外線加速老化試験機、 急速温度変化試験室、ウォークイン環境試験室、UV老化試験機、恒温恒湿室など。当社は、誠実に事業を築き、品質を維持し、進歩を目指すという原則を堅持しています。より断固としたペースで、私たちは絶えず新たな高みに登り、国の自動化産業に貢献しています。私たちは、新しい顧客と古い顧客が自信を持って好きな製品を選択することを歓迎します。私たちは心からあなたにサービスを提供します!
    続きを読む