バナー
ホーム

温度試験室

温度試験室

  • Small Rapid Temperature Change (Wet Heat) Test Chamber
    Nov 01, 2025
    In response to the testing and R&D requirements of electronic components such as semiconductors and automotive electronics, Lab Companion has developed a smaller capacity small rapid temperature change (wet heat) test chamber. While maintaining the advantages of standard rapid temperature change test chambers, it can also meet the needs of customers who have requirements for space size, with a single-phase 220VAC voltage specification. It can also meet the equipment usage requirements of customers in civilian office areas such as research institutions and universities. Its main features are as follows: 1. It has powerful heating and cooling performance 2. Heating rate: 15℃/min; Cooling rate: 15℃/min 3. (Temperature range: -45℃ to +155℃) 4. Single-phase 220VAC, meeting the electricity demands of more customers 5. Single-phase 220VAC, suitable for industrial and civil power supply specifications, can meet the equipment power demands of customers in civil office areas such as research institutions and universities. 6. The body is small and exquisite, with a compact structure and easy to move 7. The miniaturized structure design of the test chamber can effectively save configuration space. 8. The inner tank volume is 100L, the width is 600mm, the depth is less than 1400mm, and the product volume is less than 1.1m ³. It is suitable for the vast majority of residential and commercial elevators in China (GB/T7025.1). 9. The standard universal wheels enable the product to move freely at the installation site. 10. Standard air-cooled specification is provided, facilitating the movement and installation of the product 11. At the same time, it saves customers the cost and space of configuring cooling towers. 12. A more ergonomic operation touch screen design 13. Through the multi-angle adjustment of the touch screen, it can meet the operation needs and provide the best field of vision for users of different heights, making it more convenient and comfortable. 14. Energy-saving cold output temperature and humidity control system, with dual PID and water vapor partial pressure control, features mature technology and extremely high precision. 15. Network control and data acquisition can be carried out through the interface (RS-485/GPIB/Web Lan/RS-232C). 16. It is standard-equipped with left and right cable holes (50mm), which facilitates the connection of power on the sample and the conduct of multiple measurements. 17. The controller adopts a color LCD touch screen, which is simple and convenient to operate 18. Through the controller, two control methods, fixed value and program, can be selected to adapt to different applications. 19. The program control can be set to 100 modes, with 99 steps for each mode. Repeat the loop up to 999 times. 20. Multiple languages can be easily switched (Simplified Chinese, English), and test data can be stored on a USB flash drive.
    続きを読む
  • How to Prevent Condensation when Conducting Low-temperature Tests in a Temperature Test Chamber
    Oct 30, 2025
    When conducting low-temperature tests in a temperature test chamber, preventing condensation is a crucial and common issue. Condensation not only affects the accuracy of test results, but may also cause irreversible damage to products, such as short circuits, metal corrosion, and degradation of material performance.   The essence of condensation is that when the surface temperature of the product drops below the "dew point temperature" of the ambient air, water vapor in the air condenses into liquid water on the product surface. Based on this principle, the core idea for preventing condensation is to avoid the surface temperature of the product being lower than the dew point temperature of the ambient air. The specific methods are as follows:   Controlling the rate of temperature change is the most commonly used and effective method. By slowing down the rate of cooling or heating, the temperature of the product can keep up with the changes in ambient temperature, thereby reducing the temperature difference between the two and preventing the surface temperature of the product from falling below the dew point. 2. Use dry air or nitrogen to directly reduce the absolute humidity of the air inside the test chamber, thereby significantly lowering the dew point temperature. Even if the surface of the product is very cold, as long as the dew point of the ambient air is lower, condensation will not occur. It is usually used for products that are extremely sensitive to moisture, such as precision circuit boards and aerospace components, etc. 3. Local heating or insulation can ensure that the surface temperature of key components (such as circuit boards and sensors) is always above the dew point, which is more suitable for products with complex structures where only certain areas are sensitive to humidity. 4. Skillfully arrange the temperature cycle through programming to avoid exposing the product at the stage when condensation is most likely to occur. After the test is completed, do not directly open the box door in a normal temperature and humidity environment. Dry gas should first be introduced into the box and the temperature should be slowly raised to room temperature. After the product temperature has also risen, the box can be opened and taken out.   For a typical low-temperature test, the following process can be followed to prevent condensation to the greatest extent First, place the product and the test chamber in a standard laboratory environment for a sufficient period of time to stabilize their condition. Subsequently, within the range close to room temperature to "0°", set up one or more short-term insulation platforms. Or maintain it at the target low temperature for a sufficient period of time, during which the temperature inside and outside the product is consistent, and usually no new condensation will form. Also, set a heating rate that is slower than the cooling rate. Set up an insulation platform at the initial stage of temperature rise and when approaching the ambient temperature. After the temperature rise is completed, do not open the door immediately. Keep the box door closed and let the product stand in the box for "30 minutes to 2 hours" (depending on the heat capacity of the product), or introduce dry air into the box to accelerate the equalization process. After confirming that the product temperature is close to the ambient temperature, open the box door and take out the product.   The best practice is to use the above methods in combination. For instance, in most cases, "controlling the temperature variation rate" combined with "optimizing the test program (especially during the recovery stage)" can solve 90% of the condensation problems. For military or automotive electronics tests with strict requirements, it may be necessary to simultaneously stipulate the temperature variation rate and require the introduction of dry air.
    続きを読む
  • Dragon Heat Flow Meter Temperature Control Test
    Oct 29, 2025
    Temperature control tests are usually conducted under two conditions: no-load (without sample placement) and load (with standard samples or actual samples being tested placed). The basic testing steps are as follows:   1. Preparatory work: Ensure that the heat flow meter has been fully preheated and is in a stable state. Prepare high-precision temperature sensors that have undergone metrological calibration (such as multiple platinum resistance PT100), and their accuracy should be much higher than the claimed indicators of the heat flow meter to be measured. 2. Temperature uniformity test: Multiple calibrated temperature sensors are arranged at different positions within the working area of the heat flow meter's heating plate (such as the center, four corners, edges, etc.). Set one or more typical test temperature points (such as -20°C, 25°C, 80°C). After the system reaches thermal stability, simultaneously record the temperature values of all sensors. Calculate the maximum, minimum and standard deviation of these readings to evaluate the uniformity. 3. Temperature control stability and accuracy test: Fix a calibrated temperature sensor at the center of the heating plate (or closely attach it to the built-in sensor of the instrument). Set the target temperature and start the temperature control. Record the entire process from the start to reaching the target temperature (for analyzing response speed and overshoot). After reaching the target temperature, continuously record for at least 1-2 hours (or as per standard requirements), with a sampling frequency high enough (such as once per second), and analyze the recorded data. 4. Load test: Place standard reference materials with known thermal physical properties or typical samples to be tested between the hot plates. Repeat step 3 and observe the changes in temperature control performance under load conditions. Load will directly affect the thermal inertia of the system, thereby influencing the response speed and stability.   When you are choosing or using a heat flow meter, be sure to carefully review the specific parameters regarding temperature control performance in its technical specification sheet and understand under what conditions (no-load/load) these parameters were measured. Lab will provide clear and verifiable temperature control test data and reports.
    続きを読む
  • How is over-temperature protection carried out in a temperature test chamber?
    Oct 23, 2025
    The over-temperature protection of the temperature test chamber is a multi-level and multi-redundant safety system. Its core purpose is to prevent the temperature inside the chamber from rising out of control due to equipment failure, thereby protecting the safety of the test samples, the test chamber itself and the laboratory environment.   The protection system usually consists of the following key parts working together: 1. Sensor: The main sensor is used for the normal temperature control of the test chamber and provides feedback signals to the main controller. An independent over-temperature protection sensor is the key to a safety system. It is a temperature-sensing element independent of the main control temperature system (usually a platinum resistance or thermocouple), which is placed by strategically at the position within the box that best represents the risk of overheating (such as near the heater outlet or on the top of the working chamber). Its sole task is to monitor over-temperature. 2. Processing unit: The main controller receives signals from the main sensor and executes the set temperature program. The independent over-temperature protector, as an independent hardware device, is specifically designed to receive and process the signals from the over-temperature protection sensor. It does not rely on the main controller. Even if the main controller crashes or experiences a serious malfunction, it can still operate normally. 3. Actuator: The main controller controls the on and off of the heater and the cooler. The safety relay/solid-state relay receives the signal sent by the over-temperature protector and directly cuts off the power supply circuit of the heater. This is the final execution action.   The over-temperature protection of the temperature test chamber is a multi-level, hard-wire connected safety system designed based on the concepts of "redundancy" and "independence". It does not rely on the main control system. Through independent sensors and controllers, when a dangerous temperature is detected, it directly and forcibly cuts off the heating energy and notifies the user through sound and light alarms, thus forming a complete and reliable safety closed loop.
    続きを読む
  • Lab Aging Test Chamber Working Principle
    Oct 17, 2025
    Many products (such as rubber, plastic, insulating materials, electronic components, etc.) will age due to the combined effects of heat and oxygen when exposed to the natural environment over a long period of use, such as becoming hard, brittle, cracking, and experiencing a decline in performance. This process is very slow in its natural state. The air-exchange aging test chamber greatly accelerates the aging process by creating a continuously high-temperature environment and constantly replenishing fresh air in the laboratory, thereby evaluating the long-term heat aging resistance of materials in a short period of time.   The working principle of Lab aging test chamber mainly relies on the collaborative efforts of three systems: 1. The heating system provides and maintains a high-temperature environment inside the test chamber. High-performance electric heaters are usually adopted and installed at the bottom, back or in the air duct of the test chamber. After the controller sets the target temperature (for example, 150°C), the heater starts to work. The air is blown through the heater by a high-power fan. The heated air is forced to circulate inside the box, causing the temperature inside the box to rise evenly and remain at the set value. 2. The ventilation system is the key that distinguishes it from ordinary ovens. At high temperatures, the sample will undergo an oxidation reaction with oxygen in the air, consuming oxygen and generating volatile products. If the air is not exchanged, the oxygen concentration inside the box will decrease, the reaction will slow down, and it may even be surrounded by the products of the sample's own decomposition. This is inconsistent with the actual usage of the product in a naturally ventilated environment. 3. The control system precisely controls the parameters of the entire testing process. The PID (Proportional-integral-Derivative) intelligent control mode is adopted. The real-time temperature is fed back through the temperature sensor inside the box (such as platinum resistance PT100). The controller precisely adjusts the output power of the heater to ensure that the temperature fluctuation is extremely small and remains stable at the set value. Set the air exchange volume within a unit of time (for example, 50 air changes per hour). This is one of the core parameters of the air-exchange aging test chamber, which usually follows relevant test standards (such as GB/T, ASTM, IEC, etc.).   The test chamber creates a high-temperature environment through electric heaters, achieves uniform temperature inside the box by using centrifugal fans, and continuously expels exhaust gases and draws in fresh air through a unique ventilation system. Thus, under controllable experimental conditions, it simulates and accelerates the aging process of materials in a naturally ventilated thermal and oxygen environment. The biggest difference between it and a common oven lies in its "ventilation" function, which enables its test results to more truly reflect the heat aging resistance of the material during long-term use.
    続きを読む
  • 試験チャンバーに適した冷却方法を選択するには?
    Sep 09, 2025
    空冷と水冷は、冷凍装置における主流の放熱方式です。両者の最も根本的な違いは、システムで発生した熱を外部環境に放出するために使用する媒体の違いにあります。空冷は空気を使用するのに対し、水冷は水を使用します。この根本的な違いにより、設置、使用方法、コスト、適用シナリオにおいて、両者の間には多くの違いが生じています。 1. 空冷システム空冷システムの動作原理は、ファンを通して空気を強制的に送り込み、その中心となる放熱部品であるフィン付きコンデンサーに送風することで、コンデンサー内の熱を奪い、周囲の空気中に放散することです。設置は非常にシンプルで柔軟性に優れています。電源に接続するだけで稼働し、追加のサポート設備は不要なため、設置場所の改修は最小限で済みます。この冷却性能は周囲温度に大きく左右されます。暑い夏や高温で換気が不十分な環境では、空気とコンデンサーの温度差が小さくなるため、放熱効率が著しく低下し、冷却能力の低下と運転時の消費電力の増加につながります。さらに、運転中はファンの騒音が大きくなります。初期投資は通常低く、日常​​のメンテナンスも比較的容易です。主な作業は、コンデンサーフィンの汚れを定期的に清掃し、スムーズな換気を確保することです。主な運用コストは電気代です。空冷システムは、中小規模の機器、電気は豊富だが水資源が乏しい、または水へのアクセスが不便な地域、環境温度を制御できる研究室、予算が限られているプロジェクト、またはシンプルで迅速な設置プロセスを好むプロジェクトに最適です。 2. 水冷システム水冷システムの動作原理は、専用の水冷コンデンサーを通過する循環水を用いてシステムの熱を吸収・放散することです。加熱された水流は通常、屋外の冷却塔に輸送され、そこで冷却され、再び循環されます。設置は複雑で、冷却塔、水ポンプ、配水管網、水処理装置など、外部給水システム一式が必要です。これは、機器の設置場所を固定するだけでなく、敷地計画とインフラに対する高い要求を課します。システムの放熱性能は非常に安定しており、外部環境温度の変化による影響は基本的に受けません。同時に、機器本体付近の運転音は比較的低いものの、初期投資は高額です。電力消費に加えて、日常運転中の継続的な水資源消費などのコストも発生します。メンテナンス作業もより専門的で複雑であり、スケール形成、腐食、微生物の増殖を防ぐ必要があります。水冷システムは主に、大型で高出力の産業用機器、周囲温度が高い、または換気が悪い作業場、また極めて高い温度安定性と冷却効率が求められる状況に適しています。 空冷と水冷の選択は、絶対的な優劣を判断することではなく、特定の状況に最適なソリューションを見つけることです。決定は、次の考慮事項に基づいて行う必要があります。まず、大型の高出力機器は通常、安定した性能を得るために水冷を好みます。同時に、実験室の地理的気候(高温かどうか)、給水状況、設置スペース、換気状況を評価する必要もあります。次に、比較的低い初期投資を重視する場合は、空冷が適切な選択です。長期的な運用エネルギー効率と安定性を重視し、比較的高い初期構築コストを気にしない場合は、水冷の方が有利です。最後に、複雑な水システムの定期的なメンテナンスを実施できる専門的な能力があるかどうかを検討する必要があります。
    続きを読む
  • ラボコンパニオン真空オーブンの動作原理 ラボコンパニオン真空オーブンの動作原理
    Sep 02, 2025
    Lab Companion真空オーブンは、低圧条件下で材料を乾燥させる精密装置です。その動作原理は、真空状態では液体の沸点が大幅に低下するという科学的な中核原理に基づいています。その動作プロセスは、以下の3つの主要なプロセスに分けられます。 1. 真空生成:真空ポンプセットを用いてオーブンチャンバー内の空気を連続的に排出することで、内部環境を大気圧をはるかに下回るレベル(通常は10Pa、あるいはそれ以上の真空度)まで減圧します。この動作には2つの目的があります。1つ目は、チャンバー内の酸素含有量を大幅に低減し、加熱プロセス中の材料の酸化を防ぐことです。2つ目は、核となる物理プロセスである低温沸騰のための条件を作り出すことです。2. 加熱によるエネルギー供給:真空環境が確立されると、加熱システム(通常は電熱線または加熱プレートを使用)が作動を開始し、チャンバー内の材料に熱エネルギーを供給します。内部圧力が極めて低いため、材料に含まれる水分やその他の溶媒の沸点が急激に低下します。例えば、真空度が-0.085MPaの場合、水の沸点は約45℃まで低下します。これは、材料を従来の100℃まで加熱する必要がなく、内部の水分をより低い温度で急速に蒸発させることを意味します。3. 蒸気除去:蒸発によって生成された水蒸気やその他の溶剤蒸気は、材料の表面および内部から放出されます。キャビティ内の圧力差により、これらの蒸気は急速に拡散し、真空ポンプによって連続的に吸引されて外部環境に排出されます。このプロセスは継続的に進行するため、乾燥環境が維持され、キャビティ内での蒸気の再凝縮が防止されます。これにより、乾燥反応が継続的に、かつ効率的に進行し、脱水が行われます。 真空オーブンは「低温・高効率乾燥」という特徴を備えているため、医薬品、化学薬品、電子工学、食品、材料科学の分野で広く使用されており、特に貴重品、敏感な材料、従来の方法では乾燥が難しい材料の処理に適しています。
    続きを読む
  • 新エネルギー材料の研究における高温・低温試験室の応用 新エネルギー材料の研究における高温・低温試験室の応用
    Aug 30, 2025
    1. リチウムイオン電池:材料、セル、モジュールに至るまで、リチウムイオン電池の研究開発の全段階で高温および低温テストが行​​われます。 2. 材料レベル:正極材料、負極材料、電解質、セパレータなどの基礎材料について、様々な温度における基本的な物理的・化学的特性を評価します。例えば、低温における負極材料のリチウムめっきリスク試験や、高温におけるセパレータの熱収縮率(MSDS)の調査などです。 3. セルレベル:極寒地(-40℃~-20℃など)における厳しい冬をシミュレートし、バッテリーの低温始動、放電容量、レート性能を試験し、低温性能向上のためのデータサポートを提供します。高温(45℃、60℃など)でのサイクル充放電試験を実施することで、劣化を加速し、バッテリーの長期使用寿命と容量維持率を予測します。 4. 燃料電池:固体高分子型燃料電池(PEMFC)は、水と熱の管理に関して非常に厳しい要件を要求されます。コールドスタート性能は、燃料電池の実用化における重要な技術的ボトルネックです。試験室では、氷点下(例えば-30℃)の環境を模擬し、システムが凍結後に正常に起動できるかどうかを試験するとともに、氷結晶が触媒層と固体高分子型燃料電池に及ぼす機械的損傷を研究します。 5. 太陽光発電材料:太陽光パネルは屋外で25年以上使用され、昼夜を問わず四季折々の過酷な環境に耐える必要があります。昼夜の温度差(例えば、-40℃から85℃までの200サイクル)をシミュレートすることで、バッテリーセルのインターコネクトソルダーテープの熱疲労、封止材(EVA/POE)の劣化や黄ばみ、異なる積層材料間の接合信頼性などを試験し、剥離や破損を防止します。   最新の高温・低温試験室 単なる温度変化チャンバーではなく、複数の機能を統合したインテリジェントな試験プラットフォームです。この高度な試験チャンバーには観察窓と試験孔が備えられており、研究者は温度変化中のサンプルをリアルタイムで監視できます。
    続きを読む
  • 急速温度変化試験室の設置場所の選定 急速温度変化試験室の設置場所の選定
    Jun 27, 2025
    急速温度変化試験室の設置場所の選定:隣接する壁からの距離は、環境試験室の役割と特性をスムーズに発揮させるために重要です。長期間にわたって15~45℃の温度と86%を超える相対環境湿度が確保できる場所を選択してください。設置場所の動作温度は大きく変化してはなりません。 水平な面に設置する必要があります(設置時に道路の水平を確認するために水準器を使用してください)。日光が当たらない場所に設置してください。 自然換気が良好な場所に設置してください。可燃性物質、爆発性物質、高温熱源が除去された場所に設置する必要があります。ほこりの少ない場所に設置してください。電源システムのスイッチング電源にできるだけ近い場所に設置してください。
    続きを読む
  • 高温・低温試験槽に問題が発生した場合はどうすればよいですか? 高温・低温試験槽に問題が発生した場合はどうすればよいですか?
    Jun 23, 2025
    高温・低温試験室 使用の過程でさまざまな問題が発生する可能性がありますが、以下にさまざまな観点から潜在的な障害とその原因をまとめます。1. コアシステム障害温度が制御不能理由: PID 制御パラメータのバランスが崩れ、周囲温度が機器の設計範囲を超え、複数のゾーンの温度が干渉します。事例: 特殊な環境の作業場では、外部の高温により冷凍システムに過負荷がかかり、温度ドリフトが発生します。湿度が異常です理由:加湿水質が悪いと、スケールやノズルの詰まり、超音波加湿器の圧電シートの故障、除湿乾燥剤の再生不良が発生します。特殊現象:高湿度テスト中に逆結露が発生し、ボックス内の実際の湿度が設定値よりも低くなります。2. 機械的および構造的な問題空気の流れが乱れている性能:サンプルエリアには3℃以上の温度勾配があります。根本原因: カスタマイズされたサンプル ラックによって元の設計の空気ダクトが変更され、遠心ファン ブレードに汚れが蓄積して動的バランスが崩れました。 シーリング不良新たな不具合:低温時に電磁密閉ドアの磁力が低下し、-70℃を超えるとシリコン密閉ストリップが脆くなり、ひび割れが発生します。3. 電気および制御システムインテリジェント制御の失敗ソフトウェア レベル: ファームウェアのアップグレード後、温度デッド ゾーンの設定エラーが発生し、履歴データのオーバーフローによりプログラムがクラッシュします。ハードウェア レベル: SSR ソリッド ステート リレーの故障により継続的な加熱が発生し、バス通信がインバータの電磁干渉の影響を受けます。セキュリティ保護の脆弱性隠れた危険: 三重温度保護リレーの同期障害と冷媒検出器の校正期限切れによる誤報。4. 特殊な労働条件の課題特定の温度ショック問題: -40℃から+150℃への急激な変化により蒸発器の溶接部に応力割れが生じ、熱膨張係数の差により観察窓のシールが破損します。長期運転減衰性能低下: 2000 時間の連続運転後、コンプレッサーのバルブ プレートの摩耗により、冷凍能力が 15% 低下し、セラミック加熱管の抵抗値が変化してしまいます。5. 環境とメンテナンスへの影響インフラの適応事例:電源電圧の変動によるPTCヒーターの電力振動と冷却水システムのウォーターハンマー効果により、プレート式熱交換器が損傷しました。予防保守の盲点教訓: ボックスの正圧を無視すると、ベアリング室に水が入り込み、バイオフィルムが増殖して凝縮水排出パイプが詰まることになります。6. 新興技術の問題点新しい冷媒の応用課題: R404A を R448A に置き換えた後のシステム オイルの適合性の問題、および亜臨界 CO₂ 冷凍システムの高圧シールの問題。IoT統合のリスク障害: リモート制御プロトコルが悪意を持って攻撃され、プログラムの改ざんやクラウド ストレージ障害が発生し、テスト証拠チェーンが失われます。戦略の推奨事項インテリジェント診断: 振動アナライザーを設定してコンプレッサーベアリングの故障を予測し、赤外線サーモグラフィーを使用して電気接続ポイントを定期的にスキャンします。信頼性設計: 蒸発器などの主要部品は耐腐食性を向上させるために SUS316L ステンレス鋼で作られており、制御システムには冗長温度制御モジュールが追加されています。メンテナンス革新:稼働時間に基づいて動的なメンテナンス計画を実施し、年間冷媒純度検査システムを確立します。これらの問題に対する解決策は、機器の具体的なモデル、使用環境、保守履歴などを考慮して分析する必要があります。機器のOEM、第三者試験機関、ユーザーの技術チームを含む共同保守体制の構築が推奨されます。重要な試験項目については、試験の継続性を確保するために、デュアルマシンホットスタンバイシステムを構成することをお勧めします。
    続きを読む
  • Lab Companion の配信基準は何ですか? Lab Companion の配信基準は何ですか?
    Jun 23, 2025
    (1)機器の設置と試運転オンサイトサービス:技術者が無料で商品をお届けし、機械組立、電気配線、デバッグ作業を行います。デバッグパラメータは、お客様との技術契約で定められた温度、湿度、塩水噴霧の付着量、その他の指標を満たす必要があります。受入基準:第三者による測定レポートを提出し、不合格となった機器は直ちに返却または交換する。例えば、降雨試験ボックスは100%合格とする。(2)顧客研修制度操作トレーニング: 機器の起動と停止、プログラム設定、日常のメンテナンスをカバーし、品質検査機関や自動車企業などのさまざまなユーザーシナリオに合わせてカスタマイズされます。徹底したメンテナンストレーニング:故障診断(高温・低温・高湿度試験室における湿度システムのトラブルシューティングなど)やスペアパーツの交換など、お客様の自主メンテナンス能力の向上を図ります。(3)技術支援と対応即時対応: 修理要求に 15 分以内に応答し、日常的な障害を 48 時間以内に解決します (遠隔地との交渉)。リモート診断: ビデオガイダンスまたはリモート アクセス ソフトウェアを使用して、問題 (砂試験室内の異常な粉塵濃度など) を迅速に特定します。(4)スペアパーツの供給とメンテナンススペアパーツ計画を立て、協力機関(中国鉄道検査認証センター、中国電子科技集団など)からの消耗部品の供給を優先し、ダウンタイムを短縮します。保証期間中の非手動による損傷は無料で、保証期間後は明確な料金で有料サービスが提供されます。
    続きを読む
  • 夏季に氷水衝撃試験機を使用する場合、どのような点に注意すべきでしょうか? 夏季に氷水衝撃試験機を使用する場合、どのような点に注意すべきでしょうか?
    Jun 16, 2025
    広東紅展氷水衝撃試験室を夏季に使用する場合、設備の安定した動作と試験結果の正確性を確保するために、以下の事項に特に注意する必要があります。1. 環境と放熱管理 換気と放熱を強化します。夏季の高温は、機器の放熱効率の低下につながりやすいため、機器の周囲に10cm以上の空間を確保し、空気の循環を促進してください。機器が空冷システムを採用している場合は、放熱不良やコンプレッサーの過熱を防ぐため、コンデンサー表面の埃を定期的に清掃する必要があります。環境の温度と湿度を管理します。機器を直射日光の当たる場所に置かないでください。実験室の温度は25±5℃、湿度は85%未満に保つことをお勧めします。高温多湿の環境では、機器に霜や結露水が蓄積しやすくなり、除湿対策を強化する必要があります。2. 冷凍システムのメンテナンス 水質とタンク管理:夏場はバクテリアが繁殖しやすいため、硬水によるスケールの付着や配管の詰まりを防ぐため、脱イオン水または純水を使用してください。タンクの水は3日ごとに交換し、長期使用を中止する前にタンクを空にして清掃することをお勧めします。冷凍効率のモニタリング:高温環境下では、冷凍システムが過負荷状態になる可能性があります。コンプレッサーオイルの状態を定期的に点検し、冷媒が十分であることを確認してください。水温が設定値(0~4℃など)を超えた場合は、直ちに機械を停止し、トラブルシューティングを行ってください。3. 霜取りと解凍処理 霜の悪化を防ぐ 夏季の湿度が高い場合、機器内部の霜の付着が加速する可能性があります。10サイクルごとに手動で霜取りを行うことをお勧めします。設定温度を30℃に設定し、30分間保持した後、水を排出して蒸発器表面の氷結晶を除去します。長時間にわたる低温試験の連続を避けるため、試験間隔を最適化してください。機器への熱ストレスの影響を軽減するため、高温(例:160℃)と氷水ショックサイクルの間に15分間のバッファ時間を設けることをお勧めします。4. 運用仕様の調整 パラメータ設定の最適化 夏季環境の特性に応じて、常温復帰段階の時間を適切に短縮できます(基準は20秒以内に温度切り替えを完了することです)。ただし、GB/T 2423.1またはISO16750-4規格の要件を満たすようにする必要があります。安全保護を強化する必要があります。操作中は、発汗による手と低温部品の密着を防ぐため、凍結防止手袋とゴーグルを着用してください。高温テスト後にドアを開ける前に、ボックス内の温度が50℃以下であることを確認し、高温の蒸気によるやけどを防いでください。5. 緊急時および長期停止への備え 故障対応:機器にE01(温度許容範囲外)またはE02(水位異常)アラームが発生した場合は、直ちに電源を切断し、メーカーのテクニカルサポートにご連絡ください。冷凍配管をご自身で分解しないでください。長期保護:7日間以上使用しない場合は、水タンクを空にし、電源を切断して防塵カバーを取り付けてください。同時に、回路基板を乾燥した状態に保つため、半月ごとに1時間電源を入れてください。 上記の対策により、夏季の高温多湿環境が氷水衝撃試験室に与える影響を効果的に低減し、試験データの信頼性と設備の耐用年数を確保することができます。具体的な操作内容は、設備のマニュアルと実際の作業条件に応じて調整する必要があります。
    続きを読む
1 2
合計2ページ

伝言を残す

伝言を残す
弊社の製品にご興味があり、詳細を知りたい場合は、こちらにメッセージを残してください。できるだけ早く返信させていただきます。
提出する

ホーム

製品

ワッツアップ

お問い合わせ